The regulation is based on two consecutive steps:
What has changed in the regulations?
April 2, 2026 / Official Gazette No. 33212: EPDK published amendments to the Regulation on Unlicensed Electricity Generation in the Electricity Market. Effective May 1, 2026, monthly net metering was abolished, and the system switched to hourly net metering.
April 30, 2026 / Board Decision No. 14531 (Official Gazette May 5, 2026, No. 33244): New procedures and principles regarding net metering have been established; concepts such as generation, consumption, group structure, paid generation limit, and virtual meter have been redefined. Data flow has been shifted to an EPİAŞ-centered structure.
Important Scope Notes:
The new regulation applies to unlicensed renewable energy generation facilities that became eligible to receive a connection agreement invitation letter after May 12, 2019 (and facilities covered under Article 5/1(c) and (d) of the Regulation).
Residential subscriptions are excluded from this scope; their net metering continues on a monthly basis.
As a separate limit, annual production cannot exceed twice the annual total consumption of the consumption facility associated with it. No payment is made for surplus energy fed into the grid after netting that exceeds this limit; this energy is considered a free contribution to YEKDEM.
What exactly does “hourly net metering” mean?
The clearest way to explain the difference is with an example:
In monthly net metering, the energy produced and consumed over the course of a month was netted together. Excess solar energy produced during the day could offset consumption in the evening or at night of the same month.
With hourly net metering, each hour is calculated separately. Excess energy generated at 12:00 PM can only offset consumption at 12:00 PM; it does not count toward consumption at 8:00 PM.
In short, what matters now is not total production, but the overlap between production and consumption within the same hour (simultaneity).
Potential Impacts on Industrial Facilities
The impact of this change varies depending on the facility’s consumption profile:
Facilities with high daytime consumption and/or daytime shifts are relatively advantaged. Since GES production aligns with consumption during the same hours, the self-consumption rate remains high.
At facilities with consumption concentrated in the evening and at night, excess energy produced during the day cannot be offset; the self-consumption rate drops, and the payback period for the investment may be extended.
Excess production is no longer a source of revenue. Since no payment is made for surplus energy fed into the grid after offsetting, installed capacity exceeding actual demand can result in economic losses.
In general, the mindset of “whatever I produce has value” is giving way to a more disciplined model where each kilowatt-hour is evaluated within the context of hourly balance.
What should be done in this new era?
Hourly net metering is forcing solar power plant investments to adopt data- and engineering-driven planning. The steps to take are as follows:
- First, a data-driven analysis of the current situation. This is the starting point for everything. Data from consumption and generation facilities must be thoroughly examined by a team of experts; only through this analysis can the extent to which the facility’s hourly consumption curve aligns with the solar power plant’s generation curve be clearly determined.
- Technical and operational planning in the investor’s favor. Following the analysis, technical and operational changes must be planned to increase the self-consumption rate and improve the return on investment—ranging from proper sizing to storage integration.
- Load scheduling and smart energy management. Planning the timing of load usage within the facility—and even automating this process using smart energy management systems (EMS)—is of great importance. For example, identifying the times of day when electricity consumption is highest in a factory and managing non-critical loads—such as preventing your electric vehicle fleet from charging simultaneously—directly translates to savings under an hourly billing regime.
- Energy storage (BESS). Storing excess energy generated during the day and using it for evening/nighttime consumption to increase the hourly self-consumption rate is the most effective response to the new regime. Storage directly bridges the time mismatch between production and consumption.
- Group structure and portfolio optimization. Maximizing the benefits of the new structure, which allows multiple facilities to be evaluated within a single portfolio.
This type of data-driven, detailed planning requires expertise. The Dexren team conducts a detailed analysis of your operation and clearly outlines potential improvement steps. We recommend that you contact us as soon as possible to prevent financial losses that could result from hourly net metering.
Conclusion
Hourly net metering is transforming unlicensed generation in Turkey into a more data- and engineering-driven, professional field of energy management. This is not an obstacle for well-structured investments; rather, it is an opportunity that can be turned into a competitive advantage through storage and optimization.
Contact Dexren Energy to learn, through a detailed analysis, how your power plant and business are affected by hourly net metering, your self-consumption rate, and your optimization scenarios—including storage. Let’s examine your facility’s load profile together and quantify the payback period and carbon impact with concrete figures.